4: Configuration Using Web-Manager
SDS1101/2101 User Guide 31
Indicates the number of bits in a transmitted data package.
The default setting is 8.
Checks for the parity bit. The default setting is None.
The stop bit follows the data and parity bits in serial
communication. It indicates the end of transmission. The
default setting is 1.
Pack Control
Select to enable packing on the SDS.
Two firmware-selectable packing algorithms define how and
when packets are sent to the network.
The standard algorithm is optimized for applications in which
the unit is used in a local environment, allowing for very small
delays for single characters, while keeping the packet count
low.
The alternate packing algorithm minimizes the packet count
on the network and is especially useful in applications in a
routed Wide Area Network (WAN). Adjusting parameters in
this mode can economize the network data stream.
Disabled by default.
Select the maximum time for inactivity. The default time is
12 milliseconds.
Match 2 Byte Sequence Use to indicate the end of a series of data to be sent as one
group. The sequence must occur sequentially to indicate end
of the data collection to the SDS. The default setting is No.
Use to indicate the end of a series of data to be sent as one
group. Set this value to 00 if specific functions are not needed.
Send Frame Only After the detection of the byte sequence, indicates whether to
send the data frame or the entire buffer. Select Yes to send
only the data frame. The default setting is No.
Send Trailing Bytes Select the number of bytes to send after the end-of-sequence
characters. The default setting is None.
Flush Input Buffer (Serial to Network)
Select Yes to clear the input buffer with a connection that is
initiated from the device to the network. The default setting is
No.
Select Yes to clear the input buffer with a connection initiated
from the network to the device. The default setting is No.
Select Yes to clear the input buffer when the network
connection to or from the device is disconnected. The default
setting is No.