Maximum of five nested menus can be called.
No syntax checking (Enter each command correctly.)
To assign a custom user menu to a local or remote user:
set localusers add|edit <User Login> menu <Menu Name>
To create a new custom user menu or add a command to an existing custom user
menu:
set menu add <Menu Name> [command <Command Number>]
To change a command or nickname within an existing custom user menu:
set menu edit <Menu Name> command <Command Number>
set menu edit <Menu Name> nickname <Command Number>
To set the optional title for a menu:
set menu edit <Menu Name> title <Menu Title>
To enable or disable the display of command nicknames instead of commands:
set menu edit <Menu Name> shownicknames <enable|disable>
To enable or disable the redisplay of the menu before each prompt:
set menu edit <Menu Name> redisplaymenu
<enable|disable>
To delete a custom user menu or one command within a custom user menu:
set menu delete <Menu Name> [command <Command Number>]
To view a list of all menu names or all commands for a specific menu:
show menu <all|Menu Name>